QMS & EHSS Portal
v1.0 ยท May 2026
Calibration standard: Step wedge verification before each job and every 4 hours during operations per IP-NDT-UT01 Section 9. Annual UT equipment calibration per ASME Boiler & Pressure Vessel Code Section V. All field calibration approved verbally/visually by client representative before inspection commences.
๐Ÿค– FalconScan UT Crawlers โ€” 3 Units

Infrascan FalconScan magnetic crawler systems (AIR6 Systems). Each unit is independently registered and calibrated. All three units share the same calibration procedure and frequency.

EQP-001
FalconScan UT Crawler โ€” Unit #4
AIR6 Systems ยท Magnetic Crawler with UT Instrument
Operational
Unit Number
#4
Manufacturer
AIR6 Systems
Model
FalconScan
Serial Number
TBC โ€” confirm with Omar
Responsible Operator
Omar M. Alhawsawi
Annual Cal Due
Per commissioning date
๐Ÿ”ง Annual: ASME Sec V ยท Field: Pre-job + every 4 hrs (IP-NDT-UT01)
EQP-002
FalconScan UT Crawler โ€” Unit #11
AIR6 Systems ยท Magnetic Crawler with UT Instrument
Operational
Unit Number
#11
Manufacturer
AIR6 Systems
Model
FalconScan
Serial Number
TBC โ€” confirm with Omar
Responsible Operator
Omar M. Alhawsawi
Annual Cal Due
Per commissioning date
๐Ÿ”ง Annual: ASME Sec V ยท Field: Pre-job + every 4 hrs (IP-NDT-UT01)
EQP-003
FalconScan UT Crawler โ€” Unit #12
AIR6 Systems ยท Magnetic Crawler with UT Instrument
Operational
Unit Number
#12
Manufacturer
AIR6 Systems
Model
FalconScan
Serial Number
TBC โ€” confirm with Omar
Responsible Operator
Omar M. Alhawsawi
Annual Cal Due
Per commissioning date
๐Ÿ”ง Annual: ASME Sec V ยท Field: Pre-job + every 4 hrs (IP-NDT-UT01)
๐Ÿš UAV Platform โ€” 1 Unit
EQP-004
Sony Airpeak S1 UAV
Sony ยท Professional UAV Platform for Crawler Delivery
Operational
Manufacturer
Sony
Model
Airpeak S1
Serial Number
TBC โ€” confirm with Muhand
Registered Pilot
Muhand A. Fakeh
GACA Permit
UA-43495 ยท Exp Sep 2026
Max Wind (Ops)
4.2 m/s (per OPS-PJP-001)
Max Altitude (Ops)
50m AGL
Battery Type
LiPo โ€” LiPo-safe bag storage
๐Ÿ“‹ Pre-flight OEM checks before each deployment ยท Sony OEM Manual ยท GACA Part 107
๐Ÿ“ Calibration Equipment
EQP-005
Calibration Step Wedge (Carbon Steel)
UT Reference Standard โ€” Traceable Certificate Required
S/N Pending
Material
Carbon Steel
Serial Number
TBC
Calibration Lab
ISO/IEC 17025 lab โ€” to be selected
Cal Cert Expiry
TBC
โš  Traceable calibration certificate required โ€” ISO/IEC 17025 accredited lab
EQP-006
Anemometer (Wind Speed Meter)
Go/No-Go instrument for UAV operations
S/N Pending
Serial Number
TBC
Calibration Type
Functional check pre-job
Critical Threshold
4.2 m/s max for UAV ops
Responsible
Drone Pilot / SDC
Calibration Requirements Summary
EquipmentFrequencyStandardPerformed ByEvidence Required
FalconScan Crawlers #4, #11, #12 โ€” AnnualAnnually from commissioning dateASME Boiler & PV Code Section VAIR6 Systems or ISO/IEC 17025 accredited labCalibration certificate filed per unit
FalconScan Crawlers โ€” Field VerificationBefore each job + every 4 hours during operationsIP-NDT-UT01 Section 9; client requirementsCrawler Operator (UT Level II)Recorded in inspection report (IF-NDT-UT01)
Calibration Step WedgePer manufacturer / as requiredISO/IEC 17025Accredited laboratoryTraceable cert stored with standard
Sony Airpeak S1 UAVPre-flight before each deploymentSony OEM Manual; GACA Part 107Muhand A. Fakeh (GACA UA-43495)Pre-flight checklist in job file
AnemometerPre-job functional checkOPS-PJP-001 Section 6.5Drone Pilot / SDCPre-job meeting record
โ† Back to Portal
REG-EQP-001 ยท May 2026 ยท Infrascan Innovations ยท Uncontrolled If Printed