Equipment & Calibration Register
All controlled inspection equipment โ maintained by Omar M. Alhawsawi (Robotics Engineer) and COO
Calibration standard: Step wedge verification before each job and every 4 hours during operations per IP-NDT-UT01 Section 9.
Annual UT equipment calibration per ASME Boiler & Pressure Vessel Code Section V.
All field calibration approved verbally/visually by client representative before inspection commences.
๐ค FalconScan UT Crawlers โ 3 Units
Infrascan FalconScan magnetic crawler systems (AIR6 Systems). Each unit is independently registered and calibrated. All three units share the same calibration procedure and frequency.
EQP-001
Operational
FalconScan UT Crawler โ Unit #4
AIR6 Systems ยท Magnetic Crawler with UT Instrument
Unit Number
#4
Manufacturer
AIR6 Systems
Model
FalconScan
Serial Number
TBC โ confirm with Omar
Responsible Operator
Omar M. Alhawsawi
Annual Cal Due
Per commissioning date
๐ง Annual: ASME Sec V ยท Field: Pre-job + every 4 hrs (IP-NDT-UT01)
EQP-002
Operational
FalconScan UT Crawler โ Unit #11
AIR6 Systems ยท Magnetic Crawler with UT Instrument
Unit Number
#11
Manufacturer
AIR6 Systems
Model
FalconScan
Serial Number
TBC โ confirm with Omar
Responsible Operator
Omar M. Alhawsawi
Annual Cal Due
Per commissioning date
๐ง Annual: ASME Sec V ยท Field: Pre-job + every 4 hrs (IP-NDT-UT01)
EQP-003
Operational
FalconScan UT Crawler โ Unit #12
AIR6 Systems ยท Magnetic Crawler with UT Instrument
Unit Number
#12
Manufacturer
AIR6 Systems
Model
FalconScan
Serial Number
TBC โ confirm with Omar
Responsible Operator
Omar M. Alhawsawi
Annual Cal Due
Per commissioning date
๐ง Annual: ASME Sec V ยท Field: Pre-job + every 4 hrs (IP-NDT-UT01)
๐ UAV Platform โ 1 Unit
EQP-004
Operational
Sony Airpeak S1 UAV
Sony ยท Professional UAV Platform for Crawler Delivery
Manufacturer
Sony
Model
Airpeak S1
Serial Number
TBC โ confirm with Muhand
Registered Pilot
Muhand A. Fakeh
GACA Permit
UA-43495 ยท Exp Sep 2026
Max Wind (Ops)
4.2 m/s (per OPS-PJP-001)
Max Altitude (Ops)
50m AGL
Battery Type
LiPo โ LiPo-safe bag storage
๐ Pre-flight OEM checks before each deployment ยท Sony OEM Manual ยท GACA Part 107
๐ Calibration Equipment
EQP-005
S/N Pending
Calibration Step Wedge (Carbon Steel)
UT Reference Standard โ Traceable Certificate Required
Material
Carbon Steel
Serial Number
TBC
Calibration Lab
ISO/IEC 17025 lab โ to be selected
Cal Cert Expiry
TBC
โ Traceable calibration certificate required โ ISO/IEC 17025 accredited lab
EQP-006
S/N Pending
Anemometer (Wind Speed Meter)
Go/No-Go instrument for UAV operations
Serial Number
TBC
Calibration Type
Functional check pre-job
Critical Threshold
4.2 m/s max for UAV ops
Responsible
Drone Pilot / SDC
Calibration Requirements Summary
| Equipment | Frequency | Standard | Performed By | Evidence Required |
|---|---|---|---|---|
| FalconScan Crawlers #4, #11, #12 โ Annual | Annually from commissioning date | ASME Boiler & PV Code Section V | AIR6 Systems or ISO/IEC 17025 accredited lab | Calibration certificate filed per unit |
| FalconScan Crawlers โ Field Verification | Before each job + every 4 hours during operations | IP-NDT-UT01 Section 9; client requirements | Crawler Operator (UT Level II) | Recorded in inspection report (IF-NDT-UT01) |
| Calibration Step Wedge | Per manufacturer / as required | ISO/IEC 17025 | Accredited laboratory | Traceable cert stored with standard |
| Sony Airpeak S1 UAV | Pre-flight before each deployment | Sony OEM Manual; GACA Part 107 | Muhand A. Fakeh (GACA UA-43495) | Pre-flight checklist in job file |
| Anemometer | Pre-job functional check | OPS-PJP-001 Section 6.5 | Drone Pilot / SDC | Pre-job meeting record |
REG-EQP-001 ยท May 2026 ยท Infrascan Innovations ยท Uncontrolled If Printed